Showing results: 871 - 885 of 1308 items found.
-
40-298-013 -
Pickering Interfaces Ltd.
The 40-298-013 is a high density programmable resistor module with 18 channels which can be set between 2Ω and 239Ω with 1Ω resolution The 40-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
40-298-014 -
Pickering Interfaces Ltd.
The 40-298-014 is a high density programmable resistor module with 18 channels which can be set between 2Ω and 470Ω with 2Ω resolution The 40-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
40-298-010 -
Pickering Interfaces Ltd.
The 40-298-010 is a high density programmable resistor module with 18 channels which can be set between 2Ω and 31.5Ω with 0.125Ω resolution The 40-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
Extech 380562 -
Extech Instruments Corporation
Compact and precise, the Extech 380562 Milliohm Meter has 7 ranges and measures down to 0.01mΩ using 4-wire Kelvin clip test leads. Measurements are displayed on the unit's large 0.8", 1999-count LCD. Built-in comparator for Hi/Lo/Go resistance testing or selection. Complete with 4-wire cables with Kelvin clip connectors and power cord.
-
BAT-500 -
Amprobe Test Tools
Amprobe BAT-500 Battery Tester quickly and accurately tests batteries without taking the batteries off-line. This Battery Tester features a comparator function with pass/fail indication, and speed testing of batteries up to 500 Ah. Amprobe BAT-500 Battery Tester, compact and light weight, simultaneously measures battery resistance and voltage up to 40 V.
-
UI-FT05 -
Unuo Instruments
Penetration-Resistant Insert Flexing Tester, also named as Steel Midsole Flexing Tester, is used to test penetration resistant inserts flexing resistance. As described in EN 12568, ISO 20344, the inserts shall exhibit no visible signs of cracking, disintegration or delamination after having been subjected to 1 *106 (one million) flexion cycles.
-
HDYZ -
HD Power Test Equipment Co.ltd
HDYZ Transformer on-load tap changer Tester is a unique moving part that is connected with the circuit of the transformer, It is essential to test the on-load tap changer of action sequence and switching time.HDYZ Transformer On-load Tap Changer Tester is mainly applied to measure the transient waveform, transient time, transient resistance value, three-phase synchronization of transformer on-load tap-changers.
-
N1425B -
Keysight Technologies
The N1425B is designed to operate specifically with the B2985B/87B. It can hold DUTs with large terminals being used with the N1426C. The N1426A with the N1425B is available for measurements of small DUTs such as PC boards or IC sockets. The N1426B with the N1425B enables the construction of simple custom-made test leads. The N1413A High Resistance Meter Fixture Adapter is also required to connect the N1425B to the B2985B/87B.
-
N1425A -
Keysight Technologies
The N1425A is designed to operate specifically with the B2985B/87B. It can hold DUTs with large terminals being used with the N1426C. The N1426A with the N1425A is available for measurements of small DUTs such as PC boards or IC sockets. The N1426B with the N1425A enables the construction of simple custom-made test leads. The N1413A High Resistance Meter Fixture Adapter is also required to connect the N1425A to the B2985B/87B.
-
4101 IN -
Standard Electric Works Co., Ltd
● Measures Insulation Resistance, voltage (AC-DC) measurements.● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.
-
CAT Advanced Series -
Amperis sl
Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:
-
TM510 -
T&M Tools Limited Co
TM510 Surge Generator is mainly used for testing power cable high-resistance and arc-over fault whose grade range is 0-10kV, co-operating with cable fault tester and locating devices to test and locate faults. If the user choose the professional digital milli-ampere-meter, as for cable with grade range about 0- 6kV, the instrument can also be used to do DC&voltage resistance test and current leakage test after the fault is repaired. The instrument is internally equipped with voltage-rise rectifying and discharging device, has complete functions, and is also convenient and safe to be wired and operated.
-
Chroma 16502 -
Chroma Systems Solutions, Inc.
With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.
-
SCR ELEKTRONIKS
GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.
-
GWT A2 -
SCR ELEKTRONIKS
GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.